| SYSTEM OVERVIEW |
System overview: |
Standby tower UPS protects PCs and network workstations from blackouts, surges and line noise. Maintains AC output during blackouts and brownouts starting at 99V. Includes front panel LED indicators. |
Voltage compatibility: |
120V AC |
Frequency compatibility: |
60Hz |
| OUTPUT |
Output volt amp capacity (VA): |
350 |
Output watt capacity (watts): |
180 |
Output nominal voltage: |
120 |
Output voltage regulation: |
BATTERY MODE: PWM sine wave output 120V +/-5% |
Output frequency regulation: |
LINE MODE: Passes line frequency of 60Hz +/-10% BATTERY MODE: Inverter output regulated to 60Hz +/-0.5Hz |
Outlet quantity / type: |
6 NEMA 5-15R |
| INPUT |
Maximum input amps: |
10A |
Input connection type: |
NEMA 5-15P space saving right-angle plug |
Input cord length: |
6 ft, 18 gauge |
Recommended electrical service: |
15A 120V |
| BATTERY |
Full load runtime: |
2.5 minutes (350VA/180 watts) |
Half load runtime: |
10 minutes (175VA/90 watts) |
DC system voltage: |
12 VDC |
Typical battery lifespan: |
3-6 years, depending on usage |
Battery recharge rate: |
2-4 hours to 90% |
| LEDS ALARMS & SWITCHES |
Front panel LEDs: |
2 front panel LEDs confirm line power operation (green LED) and battery power operation (red LED) |
Switches: |
combination power off/on/self-test push button switch |
| SURGE / NOISE SUPPRESSION |
AC surge suppression: |
252 joules |
AC suppression response time: |
Instantaneous |
Dataline suppression: |
- |
EMI / RFI AC noise suppression: |
yes |
| PHYSICAL |
Shipping weight (lbs): |
5.6 |
Shipping weight (kg): |
2.5 |
Unit weight (lbs): |
4.7 |
Unit weight (kg): |
2.1 |
Unit Dimensions (HWD/in): |
3 x 8 x 5 |
Unit Dimensions (HWD/cm): |
7.6 x 20.3 x 12.7 |
Material of construction: |
ABS |
Form factors supported: |
Flatpack |
| ENVIRONMENTAL |
Operating Temperature: |
+32 to +104 degrees Fahrenheit 0 to +40 degrees Celsius |
Storage Temperature: |
+5 to +122 degrees Fahrenheit -15 to +50 degrees Celsius |
Relative Humidity: |
0 to 95%, non-condensing |
| COMMUNICATIONS |
Network monitoring port: |
- |
| LINE / BATTERY TRANSFER |
Transfer time from line power to battery mode: |
2-4 milliseconds |
Low voltage transfer to battery power: |
Switches to battery power as line voltage drops to 99VAC or less (user configurable to any voltage between 83 and 99VAC) |
High voltage transfer to battery power: |
Yes |
| CERTIFICATIONS |
Certifications: |
Tested to UL1778 (USA), CSA C22.2 No. 107.3 (Canada), NOM (Mexico), Class B (Emissions) |
| WARRANTY |
Optional coverage: |
Optional 3 and 5 year on site or factory warranties available for select opportunities, contact Tripp Lite for more information |
Product warranty: |
2 years |
Connected equipment insurance (USA and Canada Only): |
$100,000 connected equipment insurance (USA and Canada only) |
|